File Index
Files and directories
Sign in
FILE

pmc.json

File preview with syntax highlighting.

linux-6.19.14/tools/perf/pmu-events/arch/powerpc/power10/pmc.json JSON
  1[
  2  {
  3    "EventCode": "0x100FE",
  4    "EventName": "PM_INST_CMPL",
  5    "BriefDescription": "PowerPC instruction completed."
  6  },
  7  {
  8    "EventCode": "0x1000A",
  9    "EventName": "PM_PMC3_REWIND",
 10    "BriefDescription": "The speculative event selected for PMC3 rewinds and the counter for PMC3 is not charged."
 11  },
 12  {
 13    "EventCode": "0x10010",
 14    "EventName": "PM_PMC4_OVERFLOW",
 15    "BriefDescription": "The event selected for PMC4 caused the event counter to overflow."
 16  },
 17  {
 18    "EventCode": "0x1001C",
 19    "EventName": "PM_ULTRAVISOR_INST_CMPL",
 20    "BriefDescription": "PowerPC instruction completed while the thread was in ultravisor state."
 21  },
 22  {
 23    "EventCode": "0x100F0",
 24    "EventName": "PM_CYC",
 25    "BriefDescription": "Processor cycles."
 26  },
 27  {
 28    "EventCode": "0x10020",
 29    "EventName": "PM_PMC4_REWIND",
 30    "BriefDescription": "The speculative event selected for PMC4 rewinds and the counter for PMC4 is not charged."
 31  },
 32  {
 33    "EventCode": "0x10022",
 34    "EventName": "PM_PMC2_SAVED",
 35    "BriefDescription": "The conditions for the speculative event selected for PMC2 are met and PMC2 is charged."
 36  },
 37  {
 38    "EventCode": "0x10024",
 39    "EventName": "PM_PMC5_OVERFLOW",
 40    "BriefDescription": "The event selected for PMC5 caused the event counter to overflow."
 41  },
 42  {
 43    "EventCode": "0x1002A",
 44    "EventName": "PM_PMC3_HELD_CYC",
 45    "BriefDescription": "Cycles when the speculative counter for PMC3 is frozen."
 46  },
 47  {
 48    "EventCode": "0x1F15E",
 49    "EventName": "PM_MRK_START_PROBE_NOP_CMPL",
 50    "BriefDescription": "Marked Start probe nop (AND R0,R0,R0) completed."
 51  },
 52  {
 53    "EventCode": "0x1006C",
 54    "EventName": "PM_RUN_CYC_ST_MODE",
 55    "BriefDescription": "Cycles when the run latch is set and the core is in ST mode."
 56  },
 57  {
 58    "EventCode": "0x101E8",
 59    "EventName": "PM_THRESH_EXC_256",
 60    "BriefDescription": "Threshold counter exceeded a count of 256."
 61  },
 62  {
 63    "EventCode": "0x101EC",
 64    "EventName": "PM_THRESH_MET",
 65    "BriefDescription": "Threshold exceeded."
 66  },
 67  {
 68    "EventCode": "0x100FA",
 69    "EventName": "PM_RUN_LATCH_ANY_THREAD_CYC",
 70    "BriefDescription": "Cycles when at least one thread has the run latch set."
 71  },
 72  {
 73    "EventCode": "0x2000A",
 74    "EventName": "PM_HYPERVISOR_CYC",
 75    "BriefDescription": "Cycles when the thread is in Hypervisor state. MSR[S HV PR]=010."
 76  },
 77  {
 78    "EventCode": "0x2000C",
 79    "EventName": "PM_RUN_LATCH_ALL_THREADS_CYC",
 80    "BriefDescription": "Cycles when the run latch is set for all threads."
 81  },
 82  {
 83    "EventCode": "0x20010",
 84    "EventName": "PM_PMC1_OVERFLOW",
 85    "BriefDescription": "The event selected for PMC1 caused the event counter to overflow."
 86  },
 87  {
 88    "EventCode": "0x2006C",
 89    "EventName": "PM_RUN_CYC_SMT4_MODE",
 90    "BriefDescription": "Cycles when this thread's run latch is set and the core is in SMT4 mode."
 91  },
 92  {
 93    "EventCode": "0x201E6",
 94    "EventName": "PM_THRESH_EXC_32",
 95    "BriefDescription": "Threshold counter exceeded a value of 32."
 96  },
 97  {
 98    "EventCode": "0x201E8",
 99    "EventName": "PM_THRESH_EXC_512",
100    "BriefDescription": "Threshold counter exceeded a value of 512."
101  },
102  {
103    "EventCode": "0x200F4",
104    "EventName": "PM_RUN_CYC",
105    "BriefDescription": "Processor cycles gated by the run latch."
106  },
107  {
108    "EventCode": "0x200F8",
109    "EventName": "PM_EXT_INT",
110    "BriefDescription": "Cycles an external interrupt was active."
111  },
112  {
113    "EventCode": "0x30010",
114    "EventName": "PM_PMC2_OVERFLOW",
115    "BriefDescription": "The event selected for PMC2 caused the event counter to overflow."
116  },
117  {
118    "EventCode": "0x30020",
119    "EventName": "PM_PMC2_REWIND",
120    "BriefDescription": "The speculative event selected for PMC2 rewinds and the counter for PMC2 is not charged."
121  },
122  {
123    "EventCode": "0x30022",
124    "EventName": "PM_PMC4_SAVED",
125    "BriefDescription": "The conditions for the speculative event selected for PMC4 are met and PMC4 is charged."
126  },
127  {
128    "EventCode": "0x30024",
129    "EventName": "PM_PMC6_OVERFLOW",
130    "BriefDescription": "The event selected for PMC6 caused the event counter to overflow."
131  },
132  {
133    "EventCode": "0x3405A",
134    "EventName": "PM_PRIVILEGED_INST_CMPL",
135    "BriefDescription": "PowerPC instruction completed while the thread was in Privileged state."
136  },
137  {
138    "EventCode": "0x3006C",
139    "EventName": "PM_RUN_CYC_SMT2_MODE",
140    "BriefDescription": "Cycles when this thread's run latch is set and the core is in SMT2 mode."
141  },
142  {
143    "EventCode": "0x301E8",
144    "EventName": "PM_THRESH_EXC_64",
145    "BriefDescription": "Threshold counter exceeded a value of 64."
146  },
147  {
148    "EventCode": "0x301EA",
149    "EventName": "PM_THRESH_EXC_1024",
150    "BriefDescription": "Threshold counter exceeded a value of 1024."
151  },
152  {
153    "EventCode": "0x40010",
154    "EventName": "PM_PMC3_OVERFLOW",
155    "BriefDescription": "The event selected for PMC3 caused the event counter to overflow."
156  },
157  {
158    "EventCode": "0x40114",
159    "EventName": "PM_MRK_START_PROBE_NOP_DISP",
160    "BriefDescription": "Marked Start probe nop dispatched. Instruction AND R0,R0,R0."
161  },
162  {
163    "EventCode": "0x4D010",
164    "EventName": "PM_PMC1_SAVED",
165    "BriefDescription": "The conditions for the speculative event selected for PMC1 are met and PMC1 is charged."
166  },
167  {
168    "EventCode": "0x4D012",
169    "EventName": "PM_PMC3_SAVED",
170    "BriefDescription": "The conditions for the speculative event selected for PMC3 are met and PMC3 is charged."
171  },
172  {
173    "EventCode": "0x4D022",
174    "EventName": "PM_HYPERVISOR_INST_CMPL",
175    "BriefDescription": "PowerPC instruction completed while the thread was in hypervisor state."
176  },
177  {
178    "EventCode": "0x4D026",
179    "EventName": "PM_ULTRAVISOR_CYC",
180    "BriefDescription": "Cycles when the thread is in Ultravisor state. MSR[S HV PR]=110."
181  },
182  {
183    "EventCode": "0x4D028",
184    "EventName": "PM_PRIVILEGED_CYC",
185    "BriefDescription": "Cycles when the thread is in Privileged state. MSR[S HV PR]=x00."
186  },
187  {
188    "EventCode": "0x4D02C",
189    "EventName": "PM_PMC1_REWIND",
190    "BriefDescription": "The speculative event selected for PMC1 rewinds and the counter for PMC1 is not charged."
191  },
192  {
193    "EventCode": "0x40030",
194    "EventName": "PM_INST_FIN",
195    "BriefDescription": "Instruction finished."
196  },
197  {
198    "EventCode": "0x40134",
199    "EventName": "PM_MRK_INST_TIMEO",
200    "BriefDescription": "Marked instruction finish timeout (instruction was lost)."
201  },
202  {
203    "EventCode": "0x401EA",
204    "EventName": "PM_THRESH_EXC_128",
205    "BriefDescription": "Threshold counter exceeded a value of 128."
206  },
207  {
208    "EventCode": "0x500FA",
209    "EventName": "PM_RUN_INST_CMPL",
210    "BriefDescription": "PowerPC instruction completed while the run latch is set."
211  }
212]
~/ Read-only file preview.