File Index
Files and directories
Sign in
FILE

constants.c

File preview with syntax highlighting.

linux-6.19.14/drivers/nvme/host/constants.c C
  1// SPDX-License-Identifier: GPL-2.0
  2/*
  3 * NVM Express device driver verbose errors
  4 * Copyright (c) 2022, Oracle and/or its affiliates
  5 */
  6
  7#include "nvme.h"
  8
  9static const char * const nvme_ops[] = {
 10	[nvme_cmd_flush] = "Flush",
 11	[nvme_cmd_write] = "Write",
 12	[nvme_cmd_read] = "Read",
 13	[nvme_cmd_write_uncor] = "Write Uncorrectable",
 14	[nvme_cmd_compare] = "Compare",
 15	[nvme_cmd_write_zeroes] = "Write Zeroes",
 16	[nvme_cmd_dsm] = "Dataset Management",
 17	[nvme_cmd_verify] = "Verify",
 18	[nvme_cmd_resv_register] = "Reservation Register",
 19	[nvme_cmd_resv_report] = "Reservation Report",
 20	[nvme_cmd_resv_acquire] = "Reservation Acquire",
 21	[nvme_cmd_resv_release] = "Reservation Release",
 22	[nvme_cmd_zone_mgmt_send] = "Zone Management Send",
 23	[nvme_cmd_zone_mgmt_recv] = "Zone Management Receive",
 24	[nvme_cmd_zone_append] = "Zone Append",
 25};
 26
 27static const char * const nvme_admin_ops[] = {
 28	[nvme_admin_delete_sq] = "Delete SQ",
 29	[nvme_admin_create_sq] = "Create SQ",
 30	[nvme_admin_get_log_page] = "Get Log Page",
 31	[nvme_admin_delete_cq] = "Delete CQ",
 32	[nvme_admin_create_cq] = "Create CQ",
 33	[nvme_admin_identify] = "Identify",
 34	[nvme_admin_abort_cmd] = "Abort Command",
 35	[nvme_admin_set_features] = "Set Features",
 36	[nvme_admin_get_features] = "Get Features",
 37	[nvme_admin_async_event] = "Async Event",
 38	[nvme_admin_ns_mgmt] = "Namespace Management",
 39	[nvme_admin_activate_fw] = "Activate Firmware",
 40	[nvme_admin_download_fw] = "Download Firmware",
 41	[nvme_admin_dev_self_test] = "Device Self Test",
 42	[nvme_admin_ns_attach] = "Namespace Attach",
 43	[nvme_admin_keep_alive] = "Keep Alive",
 44	[nvme_admin_directive_send] = "Directive Send",
 45	[nvme_admin_directive_recv] = "Directive Receive",
 46	[nvme_admin_virtual_mgmt] = "Virtual Management",
 47	[nvme_admin_nvme_mi_send] = "NVMe Send MI",
 48	[nvme_admin_nvme_mi_recv] = "NVMe Receive MI",
 49	[nvme_admin_dbbuf] = "Doorbell Buffer Config",
 50	[nvme_admin_format_nvm] = "Format NVM",
 51	[nvme_admin_security_send] = "Security Send",
 52	[nvme_admin_security_recv] = "Security Receive",
 53	[nvme_admin_sanitize_nvm] = "Sanitize NVM",
 54	[nvme_admin_get_lba_status] = "Get LBA Status",
 55};
 56
 57static const char * const nvme_fabrics_ops[] = {
 58	[nvme_fabrics_type_property_set] = "Property Set",
 59	[nvme_fabrics_type_property_get] = "Property Get",
 60	[nvme_fabrics_type_connect] = "Connect",
 61	[nvme_fabrics_type_auth_send] = "Authentication Send",
 62	[nvme_fabrics_type_auth_receive] = "Authentication Receive",
 63};
 64
 65static const char * const nvme_statuses[] = {
 66	[NVME_SC_SUCCESS] = "Success",
 67	[NVME_SC_INVALID_OPCODE] = "Invalid Command Opcode",
 68	[NVME_SC_INVALID_FIELD] = "Invalid Field in Command",
 69	[NVME_SC_CMDID_CONFLICT] = "Command ID Conflict",
 70	[NVME_SC_DATA_XFER_ERROR] = "Data Transfer Error",
 71	[NVME_SC_POWER_LOSS] = "Commands Aborted due to Power Loss Notification",
 72	[NVME_SC_INTERNAL] = "Internal Error",
 73	[NVME_SC_ABORT_REQ] = "Command Abort Requested",
 74	[NVME_SC_ABORT_QUEUE] = "Command Aborted due to SQ Deletion",
 75	[NVME_SC_FUSED_FAIL] = "Command Aborted due to Failed Fused Command",
 76	[NVME_SC_FUSED_MISSING] = "Command Aborted due to Missing Fused Command",
 77	[NVME_SC_INVALID_NS] = "Invalid Namespace or Format",
 78	[NVME_SC_CMD_SEQ_ERROR] = "Command Sequence Error",
 79	[NVME_SC_SGL_INVALID_LAST] = "Invalid SGL Segment Descriptor",
 80	[NVME_SC_SGL_INVALID_COUNT] = "Invalid Number of SGL Descriptors",
 81	[NVME_SC_SGL_INVALID_DATA] = "Data SGL Length Invalid",
 82	[NVME_SC_SGL_INVALID_METADATA] = "Metadata SGL Length Invalid",
 83	[NVME_SC_SGL_INVALID_TYPE] = "SGL Descriptor Type Invalid",
 84	[NVME_SC_CMB_INVALID_USE] = "Invalid Use of Controller Memory Buffer",
 85	[NVME_SC_PRP_INVALID_OFFSET] = "PRP Offset Invalid",
 86	[NVME_SC_ATOMIC_WU_EXCEEDED] = "Atomic Write Unit Exceeded",
 87	[NVME_SC_OP_DENIED] = "Operation Denied",
 88	[NVME_SC_SGL_INVALID_OFFSET] = "SGL Offset Invalid",
 89	[NVME_SC_RESERVED] = "Reserved",
 90	[NVME_SC_HOST_ID_INCONSIST] = "Host Identifier Inconsistent Format",
 91	[NVME_SC_KA_TIMEOUT_EXPIRED] = "Keep Alive Timeout Expired",
 92	[NVME_SC_KA_TIMEOUT_INVALID] = "Keep Alive Timeout Invalid",
 93	[NVME_SC_ABORTED_PREEMPT_ABORT] = "Command Aborted due to Preempt and Abort",
 94	[NVME_SC_SANITIZE_FAILED] = "Sanitize Failed",
 95	[NVME_SC_SANITIZE_IN_PROGRESS] = "Sanitize In Progress",
 96	[NVME_SC_SGL_INVALID_GRANULARITY] = "SGL Data Block Granularity Invalid",
 97	[NVME_SC_CMD_NOT_SUP_CMB_QUEUE] = "Command Not Supported for Queue in CMB",
 98	[NVME_SC_NS_WRITE_PROTECTED] = "Namespace is Write Protected",
 99	[NVME_SC_CMD_INTERRUPTED] = "Command Interrupted",
100	[NVME_SC_TRANSIENT_TR_ERR] = "Transient Transport Error",
101	[NVME_SC_ADMIN_COMMAND_MEDIA_NOT_READY] = "Admin Command Media Not Ready",
102	[NVME_SC_INVALID_IO_CMD_SET] = "Invalid IO Command Set",
103	[NVME_SC_LBA_RANGE] = "LBA Out of Range",
104	[NVME_SC_CAP_EXCEEDED] = "Capacity Exceeded",
105	[NVME_SC_NS_NOT_READY] = "Namespace Not Ready",
106	[NVME_SC_RESERVATION_CONFLICT] = "Reservation Conflict",
107	[NVME_SC_FORMAT_IN_PROGRESS] = "Format In Progress",
108	[NVME_SC_CQ_INVALID] = "Completion Queue Invalid",
109	[NVME_SC_QID_INVALID] = "Invalid Queue Identifier",
110	[NVME_SC_QUEUE_SIZE] = "Invalid Queue Size",
111	[NVME_SC_ABORT_LIMIT] = "Abort Command Limit Exceeded",
112	[NVME_SC_ABORT_MISSING] = "Reserved", /* XXX */
113	[NVME_SC_ASYNC_LIMIT] = "Asynchronous Event Request Limit Exceeded",
114	[NVME_SC_FIRMWARE_SLOT] = "Invalid Firmware Slot",
115	[NVME_SC_FIRMWARE_IMAGE] = "Invalid Firmware Image",
116	[NVME_SC_INVALID_VECTOR] = "Invalid Interrupt Vector",
117	[NVME_SC_INVALID_LOG_PAGE] = "Invalid Log Page",
118	[NVME_SC_INVALID_FORMAT] = "Invalid Format",
119	[NVME_SC_FW_NEEDS_CONV_RESET] = "Firmware Activation Requires Conventional Reset",
120	[NVME_SC_INVALID_QUEUE] = "Invalid Queue Deletion",
121	[NVME_SC_FEATURE_NOT_SAVEABLE] = "Feature Identifier Not Saveable",
122	[NVME_SC_FEATURE_NOT_CHANGEABLE] = "Feature Not Changeable",
123	[NVME_SC_FEATURE_NOT_PER_NS] = "Feature Not Namespace Specific",
124	[NVME_SC_FW_NEEDS_SUBSYS_RESET] = "Firmware Activation Requires NVM Subsystem Reset",
125	[NVME_SC_FW_NEEDS_RESET] = "Firmware Activation Requires Reset",
126	[NVME_SC_FW_NEEDS_MAX_TIME] = "Firmware Activation Requires Maximum Time Violation",
127	[NVME_SC_FW_ACTIVATE_PROHIBITED] = "Firmware Activation Prohibited",
128	[NVME_SC_OVERLAPPING_RANGE] = "Overlapping Range",
129	[NVME_SC_NS_INSUFFICIENT_CAP] = "Namespace Insufficient Capacity",
130	[NVME_SC_NS_ID_UNAVAILABLE] = "Namespace Identifier Unavailable",
131	[NVME_SC_NS_ALREADY_ATTACHED] = "Namespace Already Attached",
132	[NVME_SC_NS_IS_PRIVATE] = "Namespace Is Private",
133	[NVME_SC_NS_NOT_ATTACHED] = "Namespace Not Attached",
134	[NVME_SC_THIN_PROV_NOT_SUPP] = "Thin Provisioning Not Supported",
135	[NVME_SC_CTRL_LIST_INVALID] = "Controller List Invalid",
136	[NVME_SC_SELF_TEST_IN_PROGRESS] = "Device Self-test In Progress",
137	[NVME_SC_BP_WRITE_PROHIBITED] = "Boot Partition Write Prohibited",
138	[NVME_SC_CTRL_ID_INVALID] = "Invalid Controller Identifier",
139	[NVME_SC_SEC_CTRL_STATE_INVALID] = "Invalid Secondary Controller State",
140	[NVME_SC_CTRL_RES_NUM_INVALID] = "Invalid Number of Controller Resources",
141	[NVME_SC_RES_ID_INVALID] = "Invalid Resource Identifier",
142	[NVME_SC_PMR_SAN_PROHIBITED] = "Sanitize Prohibited",
143	[NVME_SC_ANA_GROUP_ID_INVALID] = "ANA Group Identifier Invalid",
144	[NVME_SC_ANA_ATTACH_FAILED] = "ANA Attach Failed",
145	[NVME_SC_BAD_ATTRIBUTES] = "Conflicting Attributes",
146	[NVME_SC_INVALID_PI] = "Invalid Protection Information",
147	[NVME_SC_READ_ONLY] = "Attempted Write to Read Only Range",
148	[NVME_SC_CMD_SIZE_LIM_EXCEEDED] = "Command Size Limits Exceeded",
149	[NVME_SC_ZONE_BOUNDARY_ERROR] = "Zoned Boundary Error",
150	[NVME_SC_ZONE_FULL] = "Zone Is Full",
151	[NVME_SC_ZONE_READ_ONLY] = "Zone Is Read Only",
152	[NVME_SC_ZONE_OFFLINE] = "Zone Is Offline",
153	[NVME_SC_ZONE_INVALID_WRITE] = "Zone Invalid Write",
154	[NVME_SC_ZONE_TOO_MANY_ACTIVE] = "Too Many Active Zones",
155	[NVME_SC_ZONE_TOO_MANY_OPEN] = "Too Many Open Zones",
156	[NVME_SC_ZONE_INVALID_TRANSITION] = "Invalid Zone State Transition",
157	[NVME_SC_WRITE_FAULT] = "Write Fault",
158	[NVME_SC_READ_ERROR] = "Unrecovered Read Error",
159	[NVME_SC_GUARD_CHECK] = "End-to-end Guard Check Error",
160	[NVME_SC_APPTAG_CHECK] = "End-to-end Application Tag Check Error",
161	[NVME_SC_REFTAG_CHECK] = "End-to-end Reference Tag Check Error",
162	[NVME_SC_COMPARE_FAILED] = "Compare Failure",
163	[NVME_SC_ACCESS_DENIED] = "Access Denied",
164	[NVME_SC_UNWRITTEN_BLOCK] = "Deallocated or Unwritten Logical Block",
165	[NVME_SC_INTERNAL_PATH_ERROR] = "Internal Pathing Error",
166	[NVME_SC_ANA_PERSISTENT_LOSS] = "Asymmetric Access Persistent Loss",
167	[NVME_SC_ANA_INACCESSIBLE] = "Asymmetric Access Inaccessible",
168	[NVME_SC_ANA_TRANSITION] = "Asymmetric Access Transition",
169	[NVME_SC_CTRL_PATH_ERROR] = "Controller Pathing Error",
170	[NVME_SC_HOST_PATH_ERROR] = "Host Pathing Error",
171	[NVME_SC_HOST_ABORTED_CMD] = "Host Aborted Command",
172};
173
174const char *nvme_get_error_status_str(u16 status)
175{
176	status &= NVME_SCT_SC_MASK;
177	if (status < ARRAY_SIZE(nvme_statuses) && nvme_statuses[status])
178		return nvme_statuses[status];
179	return "Unknown";
180}
181
182const char *nvme_get_opcode_str(u8 opcode)
183{
184	if (opcode < ARRAY_SIZE(nvme_ops) && nvme_ops[opcode])
185		return nvme_ops[opcode];
186	return "Unknown";
187}
188EXPORT_SYMBOL_GPL(nvme_get_opcode_str);
189
190const char *nvme_get_admin_opcode_str(u8 opcode)
191{
192	if (opcode < ARRAY_SIZE(nvme_admin_ops) && nvme_admin_ops[opcode])
193		return nvme_admin_ops[opcode];
194	return "Unknown";
195}
196EXPORT_SYMBOL_GPL(nvme_get_admin_opcode_str);
197
198const char *nvme_get_fabrics_opcode_str(u8 opcode) {
199	if (opcode < ARRAY_SIZE(nvme_fabrics_ops) && nvme_fabrics_ops[opcode])
200		return nvme_fabrics_ops[opcode];
201	return "Unknown";
202}
203EXPORT_SYMBOL_GPL(nvme_get_fabrics_opcode_str);
~/ Read-only file preview.