File Index
Files and directories
Sign in
FILE

cdat.rst

File preview with syntax highlighting.

linux-6.19.14/Documentation/driver-api/cxl/platform/cdat.rst RESTRUCTUREDTEXT
  1.. SPDX-License-Identifier: GPL-2.0
  2
  3======================================
  4Coherent Device Attribute Table (CDAT)
  5======================================
  6
  7The CDAT provides functional and performance attributes of devices such
  8as CXL accelerators, switches, or endpoints.  The table formatting is
  9similar to ACPI tables. CDAT data may be parsed by BIOS at boot or may
 10be enumerated at runtime (after device hotplug, for example).
 11
 12Terminology:
 13DPA - Device Physical Address, used by the CXL device to denote the address
 14it supports for that device.
 15
 16DSMADHandle - A device unique handle that is associated with a DPA range
 17defined by the DSMAS table.
 18
 19
 20===============================================
 21Device Scoped Memory Affinity Structure (DSMAS)
 22===============================================
 23
 24The DSMAS contains information such as DSMADHandle, the DPA Base, and DPA
 25Length.
 26
 27This table is used by Linux in conjunction with the Device Scoped Latency and
 28Bandwidth Information Structure (DSLBIS) to determine the performance
 29attributes of the CXL device itself.
 30
 31Example ::
 32
 33 Structure Type : 00 [DSMAS]
 34       Reserved : 00
 35         Length : 0018              <- 24d, size of structure
 36    DSMADHandle : 01
 37          Flags : 00
 38       Reserved : 0000
 39       DPA Base : 0000000040000000  <- 1GiB base
 40     DPA Length : 0000000080000000  <- 2GiB size
 41
 42
 43==================================================================
 44Device Scoped Latency and Bandwidth Information Structure (DSLBIS)
 45==================================================================
 46
 47This table is used by Linux in conjunction with DSMAS to determine the
 48performance attributes of a CXL device.  The DSLBIS contains latency
 49and bandwidth information based on DSMADHandle matching.
 50
 51Example ::
 52
 53   Structure Type : 01 [DSLBIS]
 54         Reserved : 00
 55           Length : 18                     <- 24d, size of structure
 56           Handle : 0001                   <- DSMAS handle
 57            Flags : 00                     <- Matches flag field for HMAT SLLBIS
 58        Data Type : 00                     <- Latency
 59 Entry Basee Unit : 0000000000001000       <- Entry Base Unit field in HMAT SSLBIS
 60            Entry : 010000000000           <- First byte used here, CXL LTC
 61         Reserved : 0000
 62
 63   Structure Type : 01 [DSLBIS]
 64         Reserved : 00
 65           Length : 18                     <- 24d, size of structure
 66           Handle : 0001                   <- DSMAS handle
 67            Flags : 00                     <- Matches flag field for HMAT SLLBIS
 68        Data Type : 03                     <- Bandwidth
 69 Entry Basee Unit : 0000000000001000       <- Entry Base Unit field in HMAT SSLBIS
 70            Entry : 020000000000           <- First byte used here, CXL BW
 71         Reserved : 0000
 72
 73
 74==================================================================
 75Switch Scoped Latency and Bandwidth Information Structure (SSLBIS)
 76==================================================================
 77
 78The SSLBIS contains information about the latency and bandwidth of a switch.
 79
 80The table is used by Linux to compute the performance coordinates of a CXL path
 81from the device to the root port where a switch is part of the path.
 82
 83Example ::
 84
 85  Structure Type : 05 [SSLBIS]
 86        Reserved : 00
 87          Length : 20                           <- 32d, length of record, including SSLB entries
 88       Data Type : 00                           <- Latency
 89        Reserved : 000000
 90 Entry Base Unit : 00000000000000001000         <- Matches Entry Base Unit in HMAT SSLBIS
 91
 92                                                <- SSLB Entry 0
 93       Port X ID : 0100                         <- First port, 0100h represents an upstream port
 94       Port Y ID : 0000                         <- Second port, downstream port 0
 95         Latency : 0100                         <- Port latency
 96        Reserved : 0000
 97                                                <- SSLB Entry 1
 98       Port X ID : 0100
 99       Port Y ID : 0001
100         Latency : 0100
101        Reserved : 0000
102
103
104  Structure Type : 05 [SSLBIS]
105        Reserved : 00
106          Length : 18                           <- 24d, length of record, including SSLB entry
107       Data Type : 03                           <- Bandwidth
108        Reserved : 000000
109 Entry Base Unit : 00000000000000001000         <- Matches Entry Base Unit in HMAT SSLBIS
110
111                                                <- SSLB Entry 0
112       Port X ID : 0100                         <- First port, 0100h represents an upstream port
113       Port Y ID : FFFF                         <- Second port, FFFFh indicates any port
114       Bandwidth : 1200                         <- Port bandwidth
115        Reserved : 0000
116
117The CXL driver uses a combination of CDAT, HMAT, SRAT, and other data to
118generate "whole path performance" data for a CXL device.
~/ Read-only file preview.