linux-6.19.14/Documentation/devicetree/bindings/regulator/rohm,bd71815-regulator.yaml YAML
  1# SPDX-License-Identifier: GPL-2.0-only OR BSD-2-Clause
  2%YAML 1.2
  3---
  4$id: http://devicetree.org/schemas/regulator/rohm,bd71815-regulator.yaml#
  5$schema: http://devicetree.org/meta-schemas/core.yaml#
  6
  7title: ROHM BD71815 Power Management Integrated Circuit regulators
  8
  9maintainers:
 10  - Matti Vaittinen <mazziesaccount@gmail.com>
 11
 12description: |
 13  This module is part of the ROHM BD718215 MFD device. For more details
 14  see Documentation/devicetree/bindings/mfd/rohm,bd71815-pmic.yaml.
 15
 16  The regulator controller is represented as a sub-node of the PMIC node
 17  on the device tree.
 18
 19  The valid names for BD71815 regulator nodes are
 20  buck1, buck2, buck3, buck4, buck5,
 21  ldo1, ldo2, ldo3, ldo4, ldo5,
 22  ldodvref, ldolpsr, wled
 23
 24properties:
 25  wled:
 26    type: object
 27    description:
 28      properties for wled regulator
 29    $ref: regulator.yaml#
 30    unevaluatedProperties: false
 31
 32    properties:
 33      regulator-name:
 34        const: wled
 35
 36patternProperties:
 37  "^((ldo|buck)[1-5]|ldolpsr|ldodvref)$":
 38    type: object
 39    description:
 40      Properties for single LDO/BUCK regulator.
 41    $ref: regulator.yaml#
 42
 43    properties:
 44      regulator-name:
 45        pattern: "^((ldo|buck)[1-5]|ldolpsr|ldodvref)$"
 46        description:
 47          should be "ldo1", ..., "ldo5", "buck1", ..., "buck5" and "ldolpsr"
 48          for ldolpsr regulator, "ldodvref" for ldodvref reglator.
 49
 50      rohm,vsel-gpios:
 51        description:
 52          GPIO used to control ldo4 state (when ldo4 is controlled by GPIO).
 53
 54      rohm,dvs-run-voltage:
 55        description:
 56          PMIC "RUN" state voltage in uV when PMIC HW states are used. See
 57          comments below for bucks/LDOs which support this. 0 means
 58          regulator should be disabled at RUN state.
 59        $ref: /schemas/types.yaml#/definitions/uint32
 60        minimum: 0
 61        maximum: 3300000
 62
 63      rohm,dvs-snvs-voltage:
 64        description:
 65          Whether to keep regulator enabled at "SNVS" state or not.
 66          0 means regulator should be disabled at SNVS state, non zero voltage
 67          keeps regulator enabled. BD71815 does not change voltage level
 68          when PMIC transitions to SNVS.SNVS voltage depends on the previous
 69          state (from which the PMIC transitioned to SNVS).
 70        $ref: /schemas/types.yaml#/definitions/uint32
 71        minimum: 0
 72        maximum: 3300000
 73
 74      rohm,dvs-suspend-voltage:
 75        description:
 76          PMIC "SUSPEND" state voltage in uV when PMIC HW states are used. See
 77          comments below for bucks/LDOs which support this. 0 means
 78          regulator should be disabled at SUSPEND state.
 79        $ref: /schemas/types.yaml#/definitions/uint32
 80        minimum: 0
 81        maximum: 3300000
 82
 83      rohm,dvs-lpsr-voltage:
 84        description:
 85          PMIC "LPSR" state voltage in uV when PMIC HW states are used. See
 86          comments below for bucks/LDOs which support this. 0 means
 87          regulator should be disabled at LPSR state.
 88        $ref: /schemas/types.yaml#/definitions/uint32
 89        minimum: 0
 90        maximum: 3300000
 91
 92        # Bucks 1 and 2 support giving separate voltages for operational states
 93        # (RUN /CLEAN according to data-sheet) and non operational states
 94        # (LPSR/SUSPEND). The voltage is automatically changed when HW
 95        # state changes. Omitting these properties from bucks 1 and 2 leave
 96        # buck voltages to not be toggled by HW state. Enable status may still
 97        # be toggled by state changes depending on HW default settings.
 98        #
 99        # Bucks 3-5 and ldos 1-5 support setting the RUN state voltage here.
100        # Given RUN voltage is used at all states if regulator is enabled at
101        # given state.
102        # Values given for other states are regarded as enable/disable at
103        # given state (see below).
104        #
105        # All regulators except WLED support specifying enable/disable status
106        # for each of the HW states (RUN/SNVS/SUSPEND/LPSR). HW defaults can
107        # be overridden by setting voltage to 0 (regulator disabled at given
108        # state) or non-zero (regulator enabled at given state). Please note
109        # that setting non zero voltages for bucks 1/2 will also enable voltage
110        # changes according to state change.
111
112    required:
113      - regulator-name
114
115    unevaluatedProperties: false
116
117additionalProperties: false
~/ Read-only file preview.