  1What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/isku/roccatisku<minor>/actual_profile
  2Date:		June 2011
  3Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
  4Description:	The integer value of this attribute ranges from 0-4.
  5		When read, this attribute returns the number of the actual
  6		profile. This value is persistent, so its equivalent to the
  7		profile that's active when the device is powered on next time.
  8		When written, this file sets the number of the startup profile
  9		and the device activates this profile immediately.
 10Users:		http://roccat.sourceforge.net
 11
 12What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/isku/roccatisku<minor>/info
 13Date:		June 2011
 14Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
 15Description:	When read, this file returns general data like firmware version.
 16		The data is 6 bytes long.
 17		This file is readonly.
 18Users:		http://roccat.sourceforge.net
 19
 20What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/isku/roccatisku<minor>/key_mask
 21Date:		June 2011
 22Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
 23Description:	When written, this file lets one deactivate certain keys like
 24		windows and application keys, to prevent accidental presses.
 25		Profile number for which this settings occur is included in
 26		written data. The data has to be 6 bytes long.
 27		Before reading this file, control has to be written to select
 28		which profile to read.
 29Users:		http://roccat.sourceforge.net
 30
 31What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/isku/roccatisku<minor>/keys_capslock
 32Date:		June 2011
 33Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
 34Description:	When written, this file lets one set the function of the
 35		capslock key for a specific profile. Profile number is included
 36		in written data. The data has to be 6 bytes long.
 37		Before reading this file, control has to be written to select
 38		which profile to read.
 39Users:		http://roccat.sourceforge.net
 40
 41What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/isku/roccatisku<minor>/keys_easyzone
 42Date:		June 2011
 43Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
 44Description:	When written, this file lets one set the function of the
 45		easyzone keys for a specific profile. Profile number is included
 46		in written data. The data has to be 65 bytes long.
 47		Before reading this file, control has to be written to select
 48		which profile to read.
 49Users:		http://roccat.sourceforge.net
 50
 51What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/isku/roccatisku<minor>/keys_function
 52Date:		June 2011
 53Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
 54Description:	When written, this file lets one set the function of the
 55		function keys for a specific profile. Profile number is included
 56		in written data. The data has to be 41 bytes long.
 57		Before reading this file, control has to be written to select
 58		which profile to read.
 59Users:		http://roccat.sourceforge.net
 60
 61What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/isku/roccatisku<minor>/keys_macro
 62Date:		June 2011
 63Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
 64Description:	When written, this file lets one set the function of the macro
 65		keys for a specific profile. Profile number is included in
 66		written data. The data has to be 35 bytes long.
 67		Before reading this file, control has to be written to select
 68		which profile to read.
 69Users:		http://roccat.sourceforge.net
 70
 71What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/isku/roccatisku<minor>/keys_media
 72Date:		June 2011
 73Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
 74Description:	When written, this file lets one set the function of the media
 75		keys for a specific profile. Profile number is included in
 76		written data. The data has to be 29 bytes long.
 77		Before reading this file, control has to be written to select
 78		which profile to read.
 79Users:		http://roccat.sourceforge.net
 80
 81What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/isku/roccatisku<minor>/keys_thumbster
 82Date:		June 2011
 83Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
 84Description:	When written, this file lets one set the function of the
 85		thumbster keys for a specific profile. Profile number is included
 86		in written data. The data has to be 23 bytes long.
 87		Before reading this file, control has to be written to select
 88		which profile to read.
 89Users:		http://roccat.sourceforge.net
 90
 91What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/isku/roccatisku<minor>/last_set
 92Date:		June 2011
 93Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
 94Description:	When written, this file lets one set the time in secs since
 95		epoch in which the last configuration took place.
 96		The data has to be 20 bytes long.
 97Users:		http://roccat.sourceforge.net
 98
 99What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/isku/roccatisku<minor>/light
100Date:		June 2011
101Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
102Description:	When written, this file lets one set the backlight intensity for
103		a specific profile. Profile number is included in written data.
104		The data has to be 10 bytes long for Isku, IskuFX needs	16 bytes
105		of data.
106		Before reading this file, control has to be written to select
107		which profile to read.
108Users:		http://roccat.sourceforge.net
109
110What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/isku/roccatisku<minor>/macro
111Date:		June 2011
112Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
113Description:	When written, this file lets one store macros with max 500
114		keystrokes for a specific button for a specific profile.
115		Button and profile numbers are included in written data.
116		The data has to be 2083 bytes long.
117		Before reading this file, control has to be written to select
118		which profile and key to read.
119Users:		http://roccat.sourceforge.net
120
121What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/isku/roccatisku<minor>/reset
122Date:		November 2012
123Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
124Description:	When written, this file lets one reset the device.
125		The data has to be 3 bytes long.
126		This file is writeonly.
127Users:		http://roccat.sourceforge.net
128
129What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/isku/roccatisku<minor>/control
130Date:		June 2011
131Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
132Description:	When written, this file lets one select which data from which
133		profile will be	read next. The data has to be 3 bytes long.
134		This file is writeonly.
135Users:		http://roccat.sourceforge.net
136
137What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/isku/roccatisku<minor>/talk
138Date:		June 2011
139Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
140Description:	When written, this file lets one trigger easyshift functionality
141		from the host.
142		The data has to be 16 bytes long.
143		This file is writeonly.
144Users:		http://roccat.sourceforge.net
145
146What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/isku/roccatisku<minor>/talkfx
147Date:		February 2013
148Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
149Description:	When written, this file lets one trigger temporary color schemes
150		from the host.
151		The data has to be 16 bytes long.
152		This file is writeonly.
153Users:		http://roccat.sourceforge.net
~/ Read-only file preview.